PerCP/Cyanine5.5 anti-Vimentin Antibody

Pricing & Availability
Clone
O91D3 (See other available formats)
Regulatory Status
RUO
Other Names
CTRCT30, HEL 113, Epididymis Luminal Protein 113
Isotype
Mouse IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
O91D3_PerCPCyanine55_Vimentin_Antibody_1_050124
Daudi cells (negative control, open histogram) or Jurkat cells (positive control, filled histogram) were fixed and permeabilized using the True-Phos™ Perm Buffer (Cat. No. 425401), and intracellularly stained with PerCP/Cyanine5.5 anti-Vimentin (clone O91D3) or PerCP/Cyanine5.5 Mouse IgG2a, κ Isotype Control (open histogram, dashed line) (representative histogram for both cell lines) (Cat. No. 400257).
  • O91D3_PerCPCyanine55_Vimentin_Antibody_1_050124
    Daudi cells (negative control, open histogram) or Jurkat cells (positive control, filled histogram) were fixed and permeabilized using the True-Phos™ Perm Buffer (Cat. No. 425401), and intracellularly stained with PerCP/Cyanine5.5 anti-Vimentin (clone O91D3) or PerCP/Cyanine5.5 Mouse IgG2a, κ Isotype Control (open histogram, dashed line) (representative histogram for both cell lines) (Cat. No. 400257).
Compare all formats See PerCP/Cyanine5.5 spectral data
Cat # Size Price Quantity Check Availability Save
677813 25 tests 141€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
677814 100 tests 315€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Vimentin are class-III intermediate filaments found in various non-epithelial cells, especially mesenchymal cells. Vimentin is a widely expressed and highly conserved 54 kD protein that is constitutively expressed in mesenchymal cells, endothelial cells lining blood vessels, renal tubular cells, macrophages, neutrophils, fibroblasts, and leukocytes1,2. Vimentin is used as a marker of mesenchymal cells to distinguish them from epithelial cells3. Increased vimentin expression is frequently used as an EMT marker in cancer4. Autoantibodies to vimentin are commonly found in patients with autoimmune diseases such as Lupus5 and rheumatoid arthritis6, and also found after transplantation7.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Full length human vimentin produced in E. coli.
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA)
Preparation
The antibody was purified by affinity chromatography and conjugated with PerCP/Cyanine5.5 under optimal conditions.
Concentration
Lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

ICFC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by intracellular flow cytometry using our True-Phos™ Perm Buffer in Cell Suspensions Protocol. For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

* PerCP/Cyanine5.5 has a maximum absorption of 482 nm and a maximum emission of 690 nm. 

Excitation Laser
Blue Laser (488 nm)
Application Notes

While this clone recognizes mouse Vimentin, we do not recommend its usage for western blot due to poor affinity of the antibody for the protein. Additional reported applications for the relevant formats include: spatial biology (IBEX)1,2.

Additional Product Notes

For intracellular flow cytometry (ICFC), fixation/permeabilization using True-Phos™ Perm Buffer (Cat. No. 425401) is recommended.

Application References

(PubMed link indicates BioLegend citation)
  1. Radtke AJ, et al. 2020. Proc Natl Acad Sci USA. 117:33455-33465. (SB) PubMed
  2. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed

Antigen Details

Structure
466 amino acids with a predicted molecular weight of approximately 54 kD.
Distribution

Cytoplasm.

Function
Vimentins are class-III intermediate filaments found in various non-epithelial cells, especially mesenchymal cells. Vimentin is attached to the nucleus, endoplasmic reticulum, and mitochondria, either laterally or terminally.
Interaction
HCV core protein, LGSN, SYNM, PLEC, SLC6A4, STK33, LARP6, RAB8B, TOR1A, TOR1AIP1, and BCAS3.
Cell Type
B cells, Mesenchymal Stem Cells, Neural Stem Cells, Neutrophils
Biology Area
Cell Adhesion, Cell Biology, Cell Motility/Cytoskeleton/Structure, Immunology, Neuroscience, Neuroscience Cell Markers, Stem Cells
Molecular Family
Intermediate Filaments
Antigen References

1. Kidd ME, et al. 2014. Am. J. Respir. Cell Mol. Biol. 50:1.
2. Fuchs E, et al. 1994. Annu. Rev. Biochem. 63:345.
3. Zeisberg M, et al. 2009. J. Clin. Invest. 119:1429.
4. Scanlon CS, et al. 2013. J. Dent. Res. 92:114.
5. Thebault S, et al. 2002. J. Immunol. 169:4046.
6. Vossenaar ER, et al. 2004. Arthritis Res. Ther. 6:R142.
7. Rose ML. 2013. Hum. Immunol. 74:1459.

Gene ID
7431 View all products for this Gene ID
UniProt
View information about Vimentin on UniProt.org

Related FAQs

How stable is PerCP/Cyanine5.5 tandem as compared to PerCP alone?

PerCP/Cyanine5.5 is quite photostable and also better than PerCP alone in withstanding fixation.

Go To Top Version: 1    Revision Date: 05.01.2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account