LEGEND MAX™ High Sensitivity Human Granzyme B ELISA Kit

Pricing & Availability
Regulatory Status
RUO
Other Names
Granzyme 2, cytotoxic T-lymphocyte-associated serine esterase 1, CTLA1, Serine Protease B, CSP-B, CSPB, Cytotoxic serine protease B, CCP1, Cytotoxic cell protease 1
Ave. Rating
Submit a Review
Product Citations
publications
LEGEND-MAX_High-Sensitivity-Human-Granzyme-B_ELISA-Kit_062524
  • LEGEND-MAX_High-Sensitivity-Human-Granzyme-B_ELISA-Kit_062524
Cat # Size Price Save
439217 1 Pre-coated Plate ¥118,800
Description

Granzymes are serine proteases that are released by cytoplasmic granules within cytotoxic T cells and natural killer (NK) cells. Human Granzyme B is one of the five members of the human granzyme family which includes Granzymes A, B, G, H, and K. Granzyme B is expressed as a 32 kD protein encoded by the GZMB gene. While Granzyme B is mostly expressed by CTL (Cytotoxic T Lymphocyte) and NK cells, it is also expressed in resting and activated plasmacytoid dendritic cells. Granzyme B is crucial for the rapid induction of target cell apoptosis by CTL in cell-mediated immune response. Granzyme B and perforin have been shown to induce CTL-mediated target cell DNA fragmentation and apoptosis. Once released from the CTL, Granzyme B binds its receptor, the mannose-6-phosphate/insulin-like growth factor II receptor, and is endocytosed but remains arrested in endocytic vesicles until released by perforin. Once in the cytosol, Granzyme B targets caspase-3 and other caspases directly or indirectly through the mitochondria, initiating the caspase cascade which leads to DNA fragmentation and apoptosis. Elevated Granzyme B levels have been linked with various disease processes. 

The LEGEND MAX™ High Sensitivity Human Granzyme B ELISA Kit is a Sandwich Enzyme-Linked Immunosorbent Assay (ELISA) with a 96-well strip plate that is pre-coated with anti-human Granzyme B monoclonal antibody. The detection antibody is a biotinylated anti-human Granzyme B monoclonol antibody. This kit is specifically designed sensitively for the accurate quantitation of human Granzyme B in human serum, plasma, and cell culture supernatant. It is analytically validated with ready-to-use reagents.

Product Details
Technical data sheet

Kit Contents

Kit Contents
  • Human Granzyme B Pre-coated 96-well Strip Microplate
  • High Sensitivity Human Granzyme B Detection Antibody
  • Human Granzyme B Lyophilized Standard
  • Streptavidin-Polymer HRP
  • Assay Buffer A
  • Assay Buffer D
  • Substrate Solution F
  • Wash Buffer (20X)
  • Stop Solution
  • Plate Sealers

Product Details

Verified Reactivity
Human
Application

ELISA

Sensitivity
0.63 ± 0.20 pg/mL
Standard Range
1.88 - 120 pg/mL
Materials Not Included
  • Microplate reader able to measure absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 1 µL to 1,000 µL
  • Deionized water
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Plate Shaker
  • Polypropylene vials

Antigen Details

Cell Type
Dendritic cells, Granulocytes, NK cells, T cells
Biology Area
Cell Biology, Immunology, Innate Immunity, Neuroscience
Molecular Family
Enzymes and Regulators, Proteases
Gene ID
3002 View all products for this Gene ID
UniProt
View information about Granzyme B on UniProt.org

Related FAQs

In your LEGEND MAX™ ELISA Kits, there is a step that calls for washing the plates before adding sample. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The additional washing step is designed to remove these components before you start the assay. If you do not perform the washing, the effect on assay performance is negligible.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The wash buffer provided in all our LEGEND MAX™ kits is the same and the part numbers on the wash buffer bottles in these kits should be identical. For ELISA MAX™ Deluxe and ELISA MAX™ Standard Sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

In some cases, dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

Go To Top Version: 1    Revision Date: 06/25/2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account